SVS1 Visibility Sensor

The Sentry Visibility Sensor works continuously in all weather conditions to monitor changes in visibility due to rain, snow, fog, smoke and dust.

Print a SVS1 Brochure (PDF)
Print a SVS1-Tunnel Brochure (PDF)
svs1 product image
  • Overview
  • Tech Specs
  • Applications
  • Options and Accessories

Need a Quote?
Build your sensor with our Sentry Configuration Tool »


Key Features:

  • Standard Environments
  • Compact, lightweight package
  • 16km (10 mile) visibility range
  • Forward scatter measurement technique
  • Ice-resistant “look down” geometry
  • Flexible output options
  • Simple installation and maintenance

Comes with a 24-month factory warranty!

Sensor Specifications
Performance

Range:

 

Extinction Range:

Accuracy:

Time Constant:

Scatter Angle:

Source:

Outputs:

30m - 16 km standard

10m - 10 km optional

100 – 0.1863 km-1 standard; (300 – 0.30 km-1 optional)

+/- 10% RMSE

60 sec

42 deg nominal

880 nm LED

0-10 VDC analog standard

Output Options:

► 0-5 VDC analog

► 4-20 ma single ended or isolated

► Relays - 1 or 2 control & 1 diagnostic

► Serial RS-232, RS-422, or RS-485

► Wireless RF Modem

Power

DC:

AC:

10-36 VDC, 6 VA Nominal; 18 VA w/ Hood Heaters

100-240 VAC, 24 VA Nominal; 75 VA w/ Hood Heaters

Physical

Weight:

Dimensions:

Mounting:

8 kg (18 lb)

889 mm W x 292 mm H x 305 mm D (35 in x 11.5 in x 12 in)

Nominal 40 mm ISO pipe, 48 mm OD max (1-1/2” IPS pipe, 1.9 inch OD max) or

Nominal 25 mm ISO pipe, 33 mm OD max (1” IPS pipe, 1.3 inch OD max)

Environmental

Temperature:

Humidity:

Protection:

-40 to 60 C

0-100%

IP66 (NEMA-4X)

Certifications
ce logo This equipment is in compliance with the essential requirements and other provisions of Low Voltage Directives 73/23/EEC and 89/336/EEC as amended by Directive 93/68/EEC.

Please choose from one of the following Applications to view material regarding each application in PDF format:

  • airport applications
  • roads bridges application
  • coastal maritime application
  • tunnels application


Applicability:

A = Analog Output Sensor M = Serial Output Sensor A & M = Both Sensor Configurations


P/N & Name

Description / Applicability


Power Options

(-xx)

Provides the user with AC or DC power options. User must select one power option:

“AC” 100-240 VAC, 47-63 Hz

“DC” 10-36 VDC

A & M

Analog Output Options

(-y)

Provides the user with a range of analog output options. User may select one or more output options:

“-1” 0-10 VDC analog output standard

“-2” 0-5 VDC analog output optional

“-A” Standard 4-20 ma current loop option with single-ended configuration. Operates over loop resistance up to 500 ohms.

“-B” Isolated 4-20 ma current loop option for installations prone to ground loops. Operates over loop resistance up to 500 ohms.

“-C” Control relay output #1 with user selectable activate/deactivate set points. SPDT relay provides NO & NC dry contacts rated for 100 VDC @ 0.25A.

“-D” Diagnostic relay output provides remote indication of sensor status. SPDT relay provides NO & NC dry contacts rated for 100 VDC @ 0.25A.

“-E” Control relay output #2 with user selectable activate/deactivate set points. SPDT relay provides NO & NC dry contacts rated for 100 VDC @ 0.25A.

A

Serial Output Options

(-y)

Provides the Sentry™ with a powerful microprocessor to perform user selected averaging, alarms, units of measure, calibration, etc. User may select one options from the list below:

“-MA” Serial ASCII RS-232 interface for distances up to 100 ft

“-MB” Serial ASCII RS-422 interface for distances up to 4000 ft

”-MF” Serial ASCII Multidrop Addressable RS-485 interface for distances up to 4000 ft

Note - To add a control or diagnostic relay to the serial output option, add the character “C” for control relay, “D” for diagnostic relay, or “CD” for both relays to the end of the serial option ordering code. For example, “-MAC” is the ordering code for a Sentry with RS-232 output and a control relay.

M

“Add “-H” to Sentry Model Number”

External hood heaters help prevent blowing snow from clogging optics. The heaters are 25 W each for AC powered sensors and 6 W each for 12 VDC powered sensors. Thermostatically controlled to turn on at ~3o C and off at ~ 8o C.

A & M

“Add “-P” to Sentry Model Number”

Sensor mounting flange for 1-inch IPS pipe with maximum OD of 1.3 inches (33 mm).

A & M

The Sentry™ Calibration Fixture (PDF)

Used to verify the SVS1 Sentry™ sensor calibration as part of field installation and during the recommended 6 month preventative maintenance. One Calibration Fixture can be shared between several Sentry™ Visibility Sensors. It is noted that the use of a Calibration fixture to install and maintain the Sentry™ is not an optional accessory.

The Calibration Fixture consists of rugged foam-lined Attaché Case that protects and organizes the following items:

  • Light Block for checking the sensor zero

  • Neutral Density (ND) Filter for checking the sensor span

  • Scatter Plate used in conjunction with the ND Filter for checking the sensor span

  • Mounting hardware for attaching the Scatter Plate to the mounting studs on the back of the Main Electronics Enclosure.

A & M

The P/N 20014 Mounting Bracket (PDF)

An optional accessory used to mount the SVS1 Sentry Visibility Sensor with standard 1-1/2” mounting flange. It is designed to provide a durable, vibration-free installation of the Sentry and can be installed against a flat wall, traffic pole, or typical Rohn type tower leg. The design allows the Sentry to be rotated to the optimal orientation.

Key Features include:

  • High strength aluminum alloy

  • Black powder coat finish for long term weather resistance

  • 1-1/2” pipe size to mate perfectly with standard Sentry mounting flange

  • Weight: 1.1 kg (2.5 lbs)

A & M

The P/N 20016
Hood Extensions

Sentry Hood Extensions slip over the existing sensor hoods to provide additional protection from heavily contaminated air found at some sites. Typical applications include:

  • Road & bridge sites where sensor is <10m from the edge of the roadway
  • Coastal & maritime areas subject to blowing salt spray
  • Areas with heavy industrial pollution

Includes a set of 2 extensions that are easily installed and removable for sensor calibration with a screwdriver.

A & M

The Sentry™ Photometer (PDF)

Used to measure ambient background light. The photometer is typically used for airport weather AWOS systems. Algorithms in the Sentry™ Visibility Sensor automatically convert extinction coefficient to visibility using Koschmeider’s Law during the day and Allard’s Law at night.

In accordance with FAA AWOS requirements, the photometer indicates day for increasing illumination between 0.5 and 3 foot-candles (FC) and night for decreasing illumination between 3 and 0.5 FC. When configured with the photometer, the Sentry™ Visibility Sensor serial output data string includes the ambient light intensity in units of LUX as well as “D” for day and “N” for light.

Key Features include:

  • Full range spectral response

  • Interfaces to Sentry™ equipped with microprocessor option

  • Adjustable mounting hardware supplied

  • Anti-dew heater to keep window clear of condensation

 M

SentryView™ Graphical User Interface, P/N 30025 (PDF)

A Windows© based software program specially configured for interfacing the Sentry™ Visibility Sensor to the user’s personal computer. SentryView™ polls the Sentry™ sensor, collects, displays, and archives the data on the PC. SentryView™ provides a graphical display interface, report generator, data analysis, & automatic archiving. Data stored in SentryView™ can be downloaded and analyzed using common spreadsheet programs such as Microsoft Excel.

Features include:

  • Real-time graphical software

  • Powerful data presentation

  • Supports real-time and stored archived data

  • Built-in terminal program with direct connect to Sentry™ over serial interface

  • Displays daily min/max, averages, graphs, alarms, sensor diagnostics in 2 windows

  • HTML output for web browser viewing

  • Can be customized for special applications

  • Report generator for customized reporting

  • Can be easily set up and customized with a little typing and a few clicks of the mouse

 M

The XBee-PRO RS-232 RF Modem (PDF)

An IEEE 802.15.4 compliant solution that features an RS-232 or optional USB interface. Out-of-box, the modem is equipped to sustain outstanding range (2-3x the range of typical 802.15.4 solutions) and requires no additional configuration for immediate RF communications. Simply feed data into one modem, then the data is sent out the other end of the wireless link. The modem transfers a standard asynchronous serial data stream between two or more devices and is designed for rapid integration into existing data systems. Included is X-CTU software for configuring and testing XBee-PRO radio modems.

Key Features include:

  • Indoor/urban Range: up to 300’ (100 m)

  • Outdoor line-of-sight Range: up to 1 mile (1.6 km)(*)

  • Transmit Power Output: 100 mW (20 dBm) EIRP

  • Operating Frequency: 2.4 GHz

  • Receiver Sensitivity: -100 dBm

  • RS-232 or optional USB interface

  • Economic, reliable alternative to wired communications

 M

P/N 70009

AC Power Cable

US style 3-prong molded plug, 18 AWG, SJT Type, CEE color code, 3-m (10 ft).

A & M

P/N 70010-xx

Signal Cable

Optional twisted shielded pair cable, 22 AWG PVC jacket where “xx” is the length in meters. Max 30 m (100 ft).

A & M

P/N 70011-xx

DC Power Cable

Optional single pair twisted shielded pair cable, 22 AWG, PVC jacket where “xx” is the length in meters. Max 15 m (50 ft).

A & M

P/N 30023

Serial Test Cable

Serial cable connects from local RJ11 jack on Microprocessor PCB to DB9 connector on user Laptop. Used for sensor set-up and calibration using the local port. 4-m (13 ft) long.

M

P/N 30026-xxx

Serial RS-232 Output Cable

Optional twisted shielded pair cable, 22 AWG PVC jacket where “xx” is the length in meters. Max 30 m (100 ft). Prewired with DB9 Connector on one end.

M

A = Analog sensor only M = Microprocessor sensor only A & M = Both Analog and Microprocessor sensor




Home | Sensors | Consulting | About Us | Contact Us | Sitemap
EnviroTech Sensors, inc. | P.O. Box 794 | Clarksville, MD 21029 USA | 410.531.8596
©2012 Envirotech Sensors, inc. All Rights Reserved.
Site Designed and Developed by: Advantage Internet Marketing